An Extension of Cooray-Rubinstein Formula on the Calculation of Horizontal Electric Field from Inclined Lightning Channel

Authors

  • Haojiang Wan National Key Laboratory on Electromagnetic Environment Effects Army Engineering University, Shijiazhuang Branch, Shijiazhuang, 050003, China
  • Xiaojia Wang National Key Laboratory on Electromagnetic Environment Effects Army Engineering University, Shijiazhuang Branch, Shijiazhuang, 050003, China
  • Yazhou Chen National Key Laboratory on Electromagnetic Environment Effects Army Engineering University, Shijiazhuang Branch, Shijiazhuang, 050003, China
  • Xiaodong Pan National Key Laboratory on Electromagnetic Environment Effects Army Engineering University, Shijiazhuang Branch, Shijiazhuang, 050003, China
  • Xinfu Lu National Key Laboratory on Electromagnetic Environment Effects Army Engineering University, Shijiazhuang Branch, Shijiazhuang, 050003, China

Keywords:

Approximate calculation, extended Cooray-Rubinstein formula, frequency-domain, horizontal electric field, inclined lightning channel

Abstract

An approximate method to calculate the horizontal electric field from inclined lightning channel in frequency-domain was proposed based on the extension of Cooray formula and Cooray-Rubinstein formula. Validations of these two extended formulas were both performed by comparing their calculation results with those obtained by the numerical solution of Sommerfeld’s integrals using Bannister approximations. The results have shown that both the accuracy of these two extended formulas are mainly related to the observation distance and the ground conductivity, and will increase with the increasing ground conductivity and observation distance. The extended Cooray formula could predict the horizontal electric field at ground level accurately at the distance beyond 100m. And the extended Cooray-Rubinstein formula could yield an acceptable approximation on the above-ground horizontal electric field with the exception of the observation point at close range under poor ground conductivity less than 0.0001S/m.

Downloads

Download data is not yet available.

References

M. J. Master and M. A. Uman, “Lightning induced voltages on power lines: Theory,” IEEE Trans. Power Appar. and Syst., vol. PAS-103, no. 9, pp. 2502-2518, 1984.

E. M. Thomson, P. J. Medelius, M. Rubinstein, M. A. Uman, and J. Johnson, “Horizontal electric fields from lightning return strokes,” J. Geophys. Res., vol. 93, no. D3, pp. 2429-2441, 1988.

V. Cooray, “Horizontal fields generated by return strokes,” Radio Sci., vol. 27, pp. 529-537, 1992.

M. Rubinstein, “An approximate formula for the calculation of the horizontal electric field from lightning at close, intermediate and long ranges,” IEEE Trans. Electromagn. Compat., vol. 38, pp. 531-535, 1996.

F. Rachidi, C. A. Nucci, M. Ianoz, and C. Mazzetti, “Influence of a lossy ground on lightning-induced voltages on overhead lines,” IEEE Trans. Electromagn. Compat., vol. 38, no. 3, pp. 250-264, Aug. 1996.

F. Delfino, R. Procopio, M. Rossi, F. Rachidi, and C. A. Nucci, “Lightning return stroke current radiation in presence of a conducting ground: 2. Validity assessment of simplified approaches,” J. Geophys. Res., vol. 113, pp. D05111-1-D05111- 11, 2008.

J. R. Wait, “Concerning the horizontal electric field of lightning,” IEEE Trans. Electromagn. Compat., vol. 39, no. 2, pp. 186, 1997.

V. Cooray, “Some considerations on the “CoorayRubinstein” formulation used in deriving the horizontal electric field of lightning return strokes over finitely conducting ground,” IEEE Trans. Electromagn. Compat., vol. 44, no. 4, pp. 560-566, 2002.

V. Cooray, “Horizontal electric field above-and underground produced by lightning flashes,” IEEE Trans. Electromagn. Compat., vol. 52, no. 4, pp. 936-943, 2010.

G. Lupo, C. Petrarca, V. Tucci, and M. Vitelli, “EM fields generated by lightning channels with arbitrary location and slope,” IEEE Trans. Electromagn. Compat., vol 42, no. 1, pp. 39-53, Feb. 2000.

Z. Jiang, B. Zhou, and S. Qiu, “Evaluation of electromagnetic fields due to inclined lightning channel on finitely conductive ground,” 2014 Int. Conf. Lightning Protection (ICLP), Shanghai, pp. 255-259, 2014.

X. Wang, Y. Chen, H. Wan, L. Wang, and Q. Yang, “Characteristics of lightning electromagnetic fields generated by tortuous channel,” IEICE Trans. Commu., vol. E99-B, no. 7, pp. 1558-1565, 2016.

H. Wan, X. Wang, Y. Chen, X. Pan, and X. Lu, “Approximate calculation of the horizontal electric field at ground level from inclined lightning channel in frequency-domain,” 2017 International Applied Computational Electromagnetics Society (ACES) Symposium in China (ACES-China 2017), Suzhou, China, Aug. 2017.

V. Cooray, “On the accuracy of several approximate theories used in quantifying the propagation effects on lightning generated electromagnetic fields,” IEEE Trans. Antennas Propagat., vol. 56, no. 7, pp. 1960-1967, 2008.

X. Zhang and Y. Zhang, “An algorithm for calculating transient magnetic field and induced voltage inside wind turbine tower under lightning stroke,” ACES J., vol. 31, no. 1, pp. 72-78, 2016.

P. R. Bannister, Extension of Finitely Conducting Earth-Image-theory Results to Any Range, Naval Underwater Systems Center, New London, 1984.

V. Cooray, “Propagation effects due to finitely conducting ground on lightning-generated magnetic fields evaluated using Sommerfeld’s integrals,” IEEE Trans. Electromagn. Compat., vol. 51, no. 3, pp. 526-531, 2009.

V. A. Rakov and F. Rachidi, “Overview of recent progress in lightning research and lightning protection,” IEEE Trans. Electromagn. Compat., vol. 51, no. 3, pp. 428-442, 2009.

Downloads

Published

2021-07-25

How to Cite

[1]
Haojiang Wan, Xiaojia Wang, Yazhou Chen, Xiaodong Pan, and Xinfu Lu, “An Extension of Cooray-Rubinstein Formula on the Calculation of Horizontal Electric Field from Inclined Lightning Channel”, ACES Journal, vol. 33, no. 05, pp. 537–545, Jul. 2021.

Issue

Section

Articles