RF Magnetic Field Profiling with a Dielectric Bore Lining for Traveling Waves in a 3-T MRI Scanner: A Computational Study

作者

  • Milan M. Ilić 1 Electrical & Computer Engineering Department, Colorado State University, Fort Collins, CO , School of Electrical Engineering, University of Belgrade, Serbia
  • Alexey A. Tonyushkin University of Massachusetts Boston, Physics Department, Boston, MA
  • Pranav S. Athalye Electrical & Computer Engineering Department, Colorado State University, Fort Collins, CO
  • Nada J. Šekeljić Electrical & Computer Engineering Department, Colorado State University, Fort Collins, CO
  • Andrew J.M. Kiruluta Massachusetts General Hospital, Radiology Department, Boston, MA
  • Branislav M. Notaroš Electrical & Computer Engineering Department, Colorado State University, Fort Collins, CO

关键词:

3-tesla MRI, bioelectromagnetics, computational electromagnetics, magnetic resonance imaging, RF coils, RF magnetic field profiling, traveling-wave MRI

摘要

Traveling-wave magnetic resonance imaging (MRI) can be advantageous over the classical, quasistatic or near-field MRI. However, it is restricted to ultra-high static magnetic fields in the scanner and the correspondingly high RF excitation magnetic field frequencies due to fundamental constraints in cutoff frequencies of the MRI bore, considered as a waveguide. Through a computational study, we propose translating traveling-wave ideas to a 3-tesla scanner, where the RF magnetic field frequency is 127.8 MHz, using a highpermittivity dielectric layer (lining) that is built into the bore. With the lining, we can achieve traveling-wave modes inside the imaging phantoms even at 3 T, where this is generally not possible. We present results obtained using the higher order method of moments in the surface integral equation formulation, previously established as an efficient, accurate, and reliable technique for modeling of RF fields in MRI applications. Our simulations of a simple circularly polarized RF probe and dielectric lining give rise to a considerably uniform circularly polarized RF magnetic field inside phantoms in the clinical scanner.

##plugins.generic.usageStats.downloads##

##plugins.generic.usageStats.noStats##

参考

C. E. Hayes, W. A. Edelstein, J. F. Schenck, O. M. Mueller, and M. Eash, “An efficient, highly homogeneous radiofrequency coil for whole-body Nmr imaging at 1.5-T,” J Magn Reson., vol. 63, no. 3, pp. 622-8, 1985.

M. Alecci, C. M. Collins, J. Wilson, W. Liu, M. B. Smith, and P. Jezzard, “Theoretical and experimental evaluation of detached endcaps for 3 T birdcage coils,” Magn Reson Med., vol. 49, pp. 363-370, 2003.

J. T. Vaughan, G. Adriany, C. J. Snyder, J. Tian, T. Thiel, L. Bolinger, H. Liu, L. DelaBarre, and K. Ugurbil, “Efficient high-frequency body coil for high-field MRI,” Magnetic Resonance in Medicine: Official Journal of the Society of Magnetic Resonance in Medicine/Society of Magnetic Resonance in Medicine, vol. 52, no. 4, pp. 851-859, 2014.

C. A. Van den Berg, B. Van den Bergen, J. B. Van de Kamer, B. W. Raaymakers, H. Kroeze, L. W. Bartels, and J. J. W. Lagendijk, “Simultaneous B+ homogenization and specific absorption rate hotspot suppression using a magnetic resonance phased array transmit coil,” Magn Reson Med., vol. 57, pp. 577-586, 2007.

J. Tian, L. DelaBarre, J. Strupp, J. Zhang, J. Pfeuffer, M. Hamm, J. Nistler, and K. Ugurbil, “Searching for the optimal body coil design for 3T MRI,” Proceedings of the 21st Annual Meeting, International Society for Magnetic Resonance in Medicine, Salt Lake City, Utah, USA, pp. 2746,

##submission.downloads##

已出版

2020-03-01

栏目

General Submission